FIRE ALARM
FA-102T Two Zone Fire Alarm Control Panel
Features
Two Class B initiating circuits
One Class B indicating circuit (1.7 Amps)
Individual Zone Silence/Disconnect switches
Audible tones are DIP Switch selectable for Steady and Temporal Code
Powerful 3 mA capacity per zone for 2-wire smoke detectors
Common alarm Relay contact, Form C, 28 VDC @ 3 AMP (Resistive)
Selectable N.O or N.C common trouble contact 28 VDC @ 3 Amp(Resistive)
A.C. ON LED (Green)
Zone Alarm LED (Amber)
Signal Trouble LED (Amber)
Ground Fault LED (Amber)
Battery Fault LED (Amber)
Alarm Silenced LED (Amber)
Common Trouble LED & Silence switch
Remote Trouble Indicator output
Remote A.C. On output
Selectable 1 minute Signal silence inhibit
Extensive Transient Protection on all circuits
FA-1025T Five Zone Fire Alarm Control Panel
Features
Five Class B initiating circuits
Two Class B indicating circuits (1.7 Amps each)
Individual Zone Silence/Disconnect switches
Audible tones are DIP Switch selectable for Steady and Temporal Code
Powerful 3 mA capacity per zone for 2-wire smoke detectors
Common alarm Relay contact, Form C, 28 VDC @ 3 AMP (Resistive)
Selectable N.O or N.C common trouble contact
28 VDC @ 3 Amp(Resistive)A.C. ON LED (Green)
Zone Alarm LED (Amber)
Signal Trouble LED (Amber)
Ground Fault LED (Amber)
Battery Fault LED (Amber)
Alarm Silenced LED (Amber)
Common Trouble LED & Silence switch
Remote Trouble Indicator output
Remote A.C. On output
Selectable 1 minute Signal silence inhibit
Extensive Transient Protection on all circuits
Annunciator Outputs available
All circuits are power limited
FX-2000 Intelligent Fire Alarm Systems
The FX-2000 Series is ideal for residential, commercial, industrial, and institutional applications. The base system consists of one analog loop and four indicating circuits. In addition the base system supports conventional hard wired modules. With its flexible modular design, the FX-2000 Series can be configured to meet challenging requirements without compromising its easy installation and operation.
Features
Listed to UL 864, 9th edition
Modular design
Up to 500 Input Circuits
Up to 150 Output Circuits
Up to 5 Intelligent Addressable Loops
Up to 4 Remote LCD Annunciators
Up to 4 Main LED Annunciators
Up to 100 Manual Control Switches
6 or 12 Amp power supply
Three level password protection with field programmable definition
Correlatable Switch Inputs which allows for multi-functional outputs
Four Alarm Queues with selector switches Auxiliary relay contacts for Common Alarm, Common
Supervisory and Common Trouble
RS-232 output for remote system printer or CRT
History Log for alarm related events and a 2000 Event Log for all events
Front Panel Auto-Configure and/or Computer laptop
Programmable Large 4 by 20 character Back-lit LCD Display with user
Built-in One Man Walk Test operation
Configurable for Coded Operation
16 zone configurable LED annunciator complete with individual slide-in labels
Supports an RS-485 interface to the QX-5000 Voice Evacuation System
Intelligent Smoke Detector sensitivity adjustment
FA-300 Series Eight Zone LED Fire Alarm Control Panels
Features:
Listed to UL 864, 9th edition
Integrated UDACT/Digital Communicator on select models
Front panel and PC programmable
Remote upload/download capabilities
Class B (Style B) initiating circuits, configured to Class A (Style D) using converter module
Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only
Class B (Style B) indicating circuits, configured to Class A (Style Z) using converter module
Individual disconnect buttons for both initiating and indicating circuits
Audible signals may be configured for Steady, Temporal Code, California Code and March Time
Indicating Circuits
FA-300 Series Twelve Zone LED Fire Alarm Control Panels
Features:
Listed to UL 864, 9th edition Integrated UDACT/Digital Communicator on select models
Front panel and PC programmable Remote upload/download capabilities
Class B (Style B) initiating circuits, configured to Class A (Style D) using converter module
Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only
Class B (Style B) indicating circuits, configured to Class A (Style Z) using converter module
Individual disconnect buttons for both initiating and indicating circuits
Audible signals may be configured for Steady, Temporal Code, California Code and March Time
Indicating Circuits